Brink · Air Filtering
FLAIR ERV / HRV
Brink FLAIR provides balanced fresh-air supply and exhaust with MERV 13 filtration and high heat-recovery efficiency. Choose HRV for heat recovery or ERV for heat and moisture recovery, with capacity and connection orientation selected for the project.
475 Supply lists heat recovery up to 93% per HVI, PHI efficiency up to 91% and humidity recovery up to 77%. These are range maxima, not ratings shared by every model; consult the selected model's documentation.



- Applications
- Whole-house ventilation, High-performance homes, Balanced supply and exhaust, Indoor air quality
- Properties
- MERV 13, Heat recovery, Energy recovery, Constant flow, ECM motors
- System
- Balanced HRV or ERV
- Filtration
- MERV 13
- FLAIR 225 airflow
- 132 CFM (225 m³/h)
- FLAIR 325 airflow
- 192 CFM (325 m³/h)
- FLAIR 400 airflow
- 236 CFM (400 m³/h)
- FLAIR 600 airflow
- 353 CFM (600 m³/h)
- Configuration
- Left-hand or right-hand
- Heat recovery
- Up to 93% per HVI; model dependent
- PHI efficiency
- Up to 91%; model dependent
- Humidity recovery
- ERV: up to 77%; model dependent
- Motors
- Next-generation ECM
- Certifications
- UL 1812 · CSA 22.2
Product Features+
Accurate constant-flow regulation balances supply and exhaust air.
Standard unit includes a pre-heater, dry ball siphon and connections for CO₂, relative humidity and boost switches.
A 100% bypass permits shoulder-season and night-time cooling without heat recovery.
Highly insulated housing and accessible maintenance requiring one tool.
Selection & Installation+
All four sizes are available as HRV or ERV with left- or right-hand connections. Size the unit and ductwork for the project's ventilation demand.
The installation guides linked here apply specifically to the FLAIR 325 HRV and 325 ERV. Other capacities require their own model-specific installation documentation.